Figure 15 – Typical End Point Example
A better way to accomplish this is to modify the Maximum End Point for Stroke Length. If we change
the Maximum End Point value to 50% stroke length, then the maximum pump output will be limited to
50% (50% Length and 100% motor speed yields 50% output). This improves the control
characteristics as 5% to 35% flow range is now covered fully with motor speed.