Manual
11
6.4 Fastener and Fitting Inspection
All system fasteners should be checked prior to pump operation, and occasionally during use. This
would include:
The mix chamber tie-rods
Motor mounting bolts
Hardware that secures the pipe clamps to the frame
All piping unions and connection points
Most hardware can be checked simply to ensure it is not loose. However, utilize the following values
when checking the mix chamber hardware:
Mix
Chamber
Tie
Rods
Fastener
Torque
# Fasteners and size N-m In. - Lbs
(16) 3/8-16 Hex Nut
3.4
30
Motor Bolts (4) 3/8-16 x 1.75 SHCS
3.4
30
Table 6-4 Fastener
Torques