Manual

ENTER VOLUME
VOL = XX.XXX
13. Use the UP and DOWN arrow keys and the ENTER key to input the volume
pumped from the calibration column (in gallons or liters, dependent on MPC
setup).
14. Press ENTER to proceed
PUMP FLOW
CALIBRATED
15. Pump flow calibration is complete
16. Press the MENU key three times to exit back to the main operating screen.
10.5.2 Flow Method
SET STROKE 50%
FLOW = 0.0000 GPH
1. You do not have to adjust the actual stroke setting of the pump
2. Use the UP and DOWN arrow keys and the ENTER key to input the
desired flow rate (in gallons or liters per hour, dependent on MPC
setup). This should be the flow rate expected when the pump is set to
50% stroke length setting.
3. Press ENTER to proceed
SET STROKE 100%
FLOW = 000.00 GPH
4. You do not have to adjust the actual stroke setting of the pump
5. Use the UP and DOWN arrow keys and the ENTER key to input the
desired flow rate (in gallons or liters per hour, dependent on MPC
setup). This should be the flow rate expected when the pump is set to
100% stroke length setting.
6. Press ENTER to proceed
PUMP FLOW
CALIBRATED
7. Pump flow calibration is complete
8. Press the MENU key three times to exit back to the main operating
screen.