Manual
Volume Method
SET STROKE TO 50%
ENTER TO START
1. Manually adjust the stroke length of the pump to 50%
2. ** Fill your calibration column to the zero or starting point
3. Press the ENTER key
TIMER XX SEC
ENTER TO STOP
4. Allow the pump to run for any length of time you choose, dependent on flow
rate, calibration column size, process conditions, etc. The system will time out
at a maximum of 300 seconds.
5. Press the ENTER key to stop the pump
ENTER VOLUME
VOL = XX.XXX
6. Use the UP and DOWN arrow keys and the ENTER key to input the volume
pumped from the calibration column (in gallons or liters, dependent on MPC
setup).
7. Press ENTER to proceed
SET STROKE TO 100%
ENTER TO START
8. Manually adjust the stroke length of the pump to 100%
9. ** Fill your calibration column to the zero or starting point
10. Press the ENTER key
TIMER XX SEC
ENTER TO STOP
11. Allow the pump to run for any length of time you choose, dependent on flow
rate, calibration column size, process conditions, etc. The system will time out
at a maximum of 300 seconds.
12. Press the ENTER key to stop the pump