the pump to run for calibration. This calibration is also faster to complete if
the flow values are already known. The MPC display will guide the user
through the steps for calibration.
The nameplate flow rating of the pump can be used to complete the flow
calibration routine; however there will always be some variance in the
actual flow rate of a pump due to system conditions and product
characteristics. Using the pump’s nameplate rating will establish a
baseline flow rate on the MPC display; however it will not guarantee
absolute accuracy.
To Start Calibration
1. The starting display will be:
SETPT XX.XXX
FLOW XX.XXX
2. Press the MENU key
-MENU-
CALIBRATION
3. Press the ENTER key
CALIBRATION
PUMP FLOW
4. Press the ENTER key
CALIBRATION
“VOLUME”
5. To perform the Volume Method, press the ENTER key and go to the
next Section –Voume Method
6. To perform the Flow Method, press the UP arrow key
CALIBRATION
“FLOW”
7. Press the ENTER key and go to the Flow Method Section 10.5.2
If you receive the following message during the Volume calibration:
STROKE LENGTH OUT
OF RANGE
Verify that the manually set stroke length is at the correct position, either 50% or 100%.