The motor used with the MPC VECTOR is a three-phase motor; however the three-phase power is generated
internally by the MPC VECTOR itself. Do not be confused by the motor nameplate. Input power to the
MPC VECTOR is single-phase or three-phase AC 230 volts (see Section 12, Specifications for acceptable
voltage range). The nameplate on the side of your MPC VECTOR controller will list the appropriate supply
requirements for your controller.
Motor Hp Rating MPC VECTOR Input Power* Output to Motor**
1 208/230 VAC 1 or 3 phase 230 VAC 3 phase
2 208/230 VAC 1 or 3 phase 230 VAC 3 phase
3 208/230 VAC 1 or 3 phase 230 VAC 3 phase
5 208/230 VAC 3 phase only 230 VAC 3 phase
* all input ratings are 50 or 60 Hz
** output to pump motor is always 60 Hz maximum frequency
The AC drive used in the MPC VECTOR maintains tight control over voltage and current supplied to the
pump motor. This results in lower motor operating temperatures and less stress on motor windings, resulting
in longer motor life and more reliable overall operation. Further motor selection information can be found in
Section 12, Specifications at the end of this manual.
1.2 MPC VECTOR Standard Features
User keypad and display for ease of operation
Display pump operation in GPH, LPH, GPM, LPM, or RPM
One 4-20 mA analog input signal for flow control
One analog (mA) input for flow feedback control (with an external, user supplied flow metering device
which provides an analog signal)
Sensorless vector motor speed control
Two configurable digital inputs
Three configurable digital outputs (transistor type, 40 VDC maximum)
Analog 4-20 mA feedback output
NEMA 4X and IP56 ratings (for controller housing)
230 Volts, 50 or 60 Hz, single or three phase AC power for 1 through 3 Hp systems
230 Volts, 50 or 60 Hz, three phase (only) AC power for 5 Hp systems
Security code lockout of menus
Standard configurable pump protection utilizing proprietary PulsaGuard technology