Manual
46
Pump Size Bolt Position Bolt Size
Recommended
Torque
in-lbs N-m
Eclipse Standard/Eclipse Hypo
02
Front Cover / Housing 10 - 32 15 1.7
Housing Adaptor -to- Spool 1/4 - 20 48 .4
Spool -to- Motor Adaptor or
Motor 3/8 - 16 72 8.1
Motor Adaptor -to- Motor
56C 3/8 - 16 72 8.1
63 B14 M5 - 0.80 24 2.7
80 B14 M6 - 1.00 48 5.4
Eclipse Standard/Eclipse Hypo
05 and 12
Front Cover 1/4 - 20 60 6.8
Housing -to- Spool 1/4 - 20 60 6.8
Spool -to- Motor Adaptor or
Motor 3/8 - 16 72 8.1
Motor Adaptor -to- Motor
56C 3/8 - 16 72 8.1
143TC - 182C 3/8 - 16 72 8.1
63 B14 M5 - 0.80 24 2.7
80 B14 M6 - 1.00 48 5.4
Eclipse Standard/Eclipse Hypo
25
Front Cover 1/4 - 20 72 8.1
Housing -to- Spool 3/8 - 16 120 13.6
Spool -to- Motor Adaptor 3/8 - 16 120 13.6
Base Mount -to- Spool 3/8 - 16 120 13.6
Flange Bolts (min. to seal) Varies 120 13.6
Motor Adaptor -to- Motor
56C 72 8.1
143TC - 182C 3/8 - 16 120 13.6
100 - 112 B14 M8 - 1.25 120 13.6
Eclipse Standard/Eclipse Hypo
75 and 125
Front Cover 3/8 - 16 120 13.6
Housing -to- Spool 3/8 - 16 120 13.6
Spool -to- Motor Adaptor 3/8 - 16 120 13.6
Base Mount -to- Spool 3/8 - 16 120 13.6
Flange Bolts (min. to seal) Varies 120 13.6
Motor Adaptor -to- Motor
143TC - 182C 3/8 - 16 120 13.6
1182TC - 184TC 1/2 - 13 120 13.6
2213TC - 215TC
1/2 - 13
120 13.6
2254TC - 256TC
1/2 - 13
120 13.6
1100 - 112 B14 M8 - 1.25 120 13.6
1132 B34 M8 - 1.25 120 13.6