Manual

45
Maximum Sound Levels
Pump Size Sound Level (dB)
Eclipse Standard/Eclipse Hypo 02 80
Eclipse Standard/Eclipse Hypo 05 81
Eclipse Standard/Eclipse Hypo 12 82
Eclipse Standard/Eclipse Hypo 25 83
Eclipse Standard/Eclipse Hypo 75 85
Eclipse Standard/Eclipse Hypo 125 95
Maximum Flange Loads
Pump Size Flange Loads lb (N) Flange Loads Ft-lb (N-m)
Eclipse Standard/Eclipse Hypo 02 25 (111) 10 (13.5)
Eclipse Standard/Eclipse Hypo 05 25 (111) 20 (27)
Eclipse Standard/Eclipse Hypo 12 25 (111) 25 (33)
Eclipse Standard/Eclipse Hypo 25 30 (133) 20 (27)
Eclipse Standard/Eclipse Hypo 75, & 125 50 (222) 25 (34)
Maximum Suction Lift (Dry or Wetted Pump)
Pump Size Feet (m)
Eclipse Standard/Eclipse Hypo 02 3 (0.9)
Eclipse Standard/Eclipse Hypo 05 3 (0.9)
Eclipse Standard/Eclipse Hypo 12 3 (0.9)
Eclipse Standard/Eclipse Hypo 25 5 (1.5)
Eclipse Standard/Eclipse Hypo 75, & 125 5 (1.5)
NPSH Required
NPSHr = 2 ft (0.6m) at 1750rpm – All Sizes
Vacuum Systems – Flooded Suction
Maximum vacuum of 28 in-Hg (14 psi- gauge) or 0.1mm Hg (Absolute)
Solids Handling Capability
Size: 70 Microns / 0.003 inches / 0.07 mm
Maximum Concentrations: 10%
200 Mesh strainer recommended