STANDARD ACCESSORIES
Series 100/150/100D/150D/200: Pumps with tubing connections come with foot valve/strainer/weight, 4' of suction tubing, bleed
Series 100D and 150D
Offering the same features as the Series 100 and 150 Models but configured
as duplex units capable of dosing 2 chemicals at different rates.
Note: Standard Features do not add to the pump price.
Remember that liquid end adders must
be doubled for duplex pump models.
1_ _ _ - _
_
-_ _ _
_
_ _ _
MODELS:
144
=4.
0
gpd
(0
.
63
lph
)
/
4.
0
gpd
(0
.
63
lph
)
max pres.: 5
0
P
S
I
(3
.5 BAR
)
145
=5.
0
gpd
(0
.7
9
lph
)
/
4.
0
gpd
(0
.
63
lph
)
max pres.: 5
0
P
S
I
(3
.5 BAR
)
155
=5.
0
gpd
(0
.7
9
lph
)
/
5.
0
gpd
(0
.7
9
lph
)
max pres.: 5
0
P
S
I
(3
.5 BAR
)
244
=
6
.5 gpd
(1
.
03
lph
)
/
6
.5 gpd
(1
.
03
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
245
= 7.5 gpd
(1
.
18
lph
)
/
6
.5 gpd
(1
.
03
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
255
= 7.5 gpd
(1
.
18
lph
)
/
7.5 gpd
(1
.
18
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
264
= 12.0 gpd
(
1.89 lph
)
/
8.0 gpd
(
1.26 lph
)
max pres.: 60 P
S
I
(
4.2 BAR
)
265
=
12
.
0
gpd
(1
.
89
lph
)
/
9
.
0
gpd
(1
.4
3
lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
344
=
1
4.
0
gpd
(2
.
21
lph
)
/
1
4.
0
gpd
(2
.
21
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
345
=
18
.
0
gpd
(2
.
8
4 lph
)
/
1
4.
0
gpd
(2
.
21
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
355
= 18.0 gpd
(
2.84 lph
)
/
18.0 gpd
(
2.84 lph
)
max pres.: 75 P
S
I
(
5.25 BAR
)
364
=
2
5.
0
gpd
(3
.
9
4 lph
)
/
1
5.
0
gpd
(2
.
3
7 lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
365
=
2
5.
0
gpd
(3
.
9
4 lph
)
/
19
.
0
gpd
(3
.
0
lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
444
=
30
.
0
gpd
(
4.7
2
lph
)
/
30
.
0
gpd
(
4.7
2
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
445
= 30.0 gpd
(
4.72 lph
)
/
33.0 gpd
(
5.20 lph
)
max pres.: 75 P
S
I
(
5.25 BAR
)
455
=
33
.
0
gpd
(
5.
20
lph
)
/
33
.
0
gpd
(
5.
20
lph
)
max pres.: 75 P
S
I
(
5.
2
5 BAR
)
464
=
69
.
0
gpd
(10
.
88
lph
)
/
32
.
0
gpd
(
5.
0
5 lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
465
=
69
.
0
gpd
(10
.
88
lph
)
/
2
4.
0
gpd
(
3
.7
9
lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
466
=
69
.
0
gpd
(10
.
88
lph
)
/
69
.
0
gpd
(10
.
88
lph
)
max pres.:
60
P
S
I
(
4.
2
BAR
)
EL ECT RI CA L : XA
=
11
5V,
60
Hz
XB
=
230
V, 5
0
Hz
XC
=
230
V,
60
Hz
LIQUID END AAA
=
C
lear PV
C
/
CS
PE
/
C
eramic
MATERIALS: AAB
=
C
lear PV
C
/
CS
PE
/
TF
E
Pump Head
&
ABA
=
C
lear PV
C
/
Viton
/
C
eramic
Fittings
/S
eats
ABB
=
C
lear PV
C
/
Viton
/
TF
E
&
O
-rings
/
Balls
ACA
=
C
lear PV
C
/
TFE
/
Viton
/
C
eramic
AHA
=
C
lear PV
C
/
TFE
/CS
PE
/
C
eramic
BAA
=PV
C
/
CS
PE
/
C
eramic
BAB
=PV
C
/
CS
PE
/
TF
E
BBA
=PV
C
/
Viton
/
C
eramic
BBB
=PV
C
/
Viton
/
TF
E
BHA
= PV
C
/
TFE
/CS
PE
/
C
eramic
DAA
=PP
/
CS
PE
/
C
eramic
DAB
=PP
/
CS
PE
/
TF
E
DBA
=PP
/
Viton
/
C
eramic
DBB
=PP
/
Viton
/
TF
E
GFA
=
C
lear PV
C
/
TFE
/
C
eramic
(
dbl
)
GFB
=
C
lear PV
C
/
TFE
/
TFE
(
dbl
)
EFC
=
316SS
/
TFE
/
316SS
(
dbl
)
CONNECTION A
= Tubing .44" PV
C
S
uction
/
.50" PE Discharge
SIZES: C
= Tubing .
38
" PV
C
S
uction
/
.
38
" PE Discharge
F
= Tubing .44" PV
C
S
uction
/
.5
0
" PE BLK Discharge
S
= Tubing .
38
" PV
C
S
uction
/
.
38
" PE BLK Discharge
X w/ 316
=.25" FNPT
S
uction
/
.25" FNPT Discharge
SUFFIX XXX
=
S
tandard
CODES: 001
=
C
urrent Interrupter
500*
= Five Function Valve
520*
= Five Function Degas Valve
ITS
=
1
5 gal IT
S
Tank
S
yste
m
Chem-Tech Series 100D and 150D Duplex Selection Guide
Series 100D Duplex Pump
Series 150D
* Not available in SS. Adder price is per head.
A completed model number should look like "1445-XA-BAAAXXX"
Mechanical Diaphragm
Pumps
Model ETL ETLsan
All 60Hz X X
100-150 50Hz
200 50Hz
Standard Agency Listings
C
ontact
f
actory
f
or alternate listings
Contact
factory for
applicable
agency
approvals.