Specifications

26
Series C
Key Features
 Automatic Control by external pacing with prime switch (optional).
 Manual Control by on-line adjustable stroke length (fixed stroke rate).
 Liquid Low Level Option available to prevent loss of prime.
 Agency approved for demanding OUTDOOR and indoor applications.
 Highly Reliable timing circuit.
 Water Resistant excellent for OUTDOOR and indoor applications.
 Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
 Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
 Premium Standard Wetted Component Materials.
 Few Moving Parts and Wall Mountable.
 Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
Pressure and Flow Rate Capacity
LC02 LC03 LC04 LC54
Capacity GPH 0.25 0.50 1.00 1.25
nominal GPD 6 12 24 30
(max.) LPH 0.9 1.9 3.8 4.7
Pressure PSIG 80 80 80 80
(max.) BAR 5.6 5.6 5.6 5.6
Connections
Piping
1/4" FNPT
MODEL
Tubing
1/4" ID X 3/8" OD
3/8" ID X 1/2" OD
Electronic Metering Pumps
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS:
1000 CPS
Stroke Frequency Max SPM:
125
Stroke Length Turn-Down Ratio:
10:1
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115 VAC; Amps:
0.6 Amps
@ 230 VAC; Amps:
0.3 Amps @ 230 VAC
Peak Input Power:
130 Watts
Average Input Power @ Max SPM:
50 Watts