Specifications
26
Series C
Key Features
Automatic Control by external pacing with prime switch (optional).
Manual Control by on-line adjustable stroke length (fixed stroke rate).
Liquid Low Level Option available to prevent loss of prime.
Agency approved for demanding OUTDOOR and indoor applications.
Highly Reliable timing circuit.
Water Resistant excellent for OUTDOOR and indoor applications.
Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
Premium Standard Wetted Component Materials.
Few Moving Parts and Wall Mountable.
Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
Pressure and Flow Rate Capacity
LC02 LC03 LC04 LC54
Capacity GPH 0.25 0.50 1.00 1.25
nominal GPD 6 12 24 30
(max.) LPH 0.9 1.9 3.8 4.7
Pressure PSIG 80 80 80 80
(max.) BAR 5.6 5.6 5.6 5.6
Connections
Piping
1/4" FNPT
MODEL
Tubing
1/4" ID X 3/8" OD
3/8" ID X 1/2" OD
Electronic Metering Pumps
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS:
1000 CPS
Stroke Frequency Max SPM:
125
Stroke Length Turn-Down Ratio:
10:1
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115 VAC; Amps:
0.6 Amps
@ 230 VAC; Amps:
0.3 Amps @ 230 VAC
Peak Input Power:
130 Watts
Average Input Power @ Max SPM:
50 Watts