Specifications
22
Series T7
Feed Control with 7 Day Timer
The Series T7 was designed to feed chemical products on a timed sched-
ule. Typical applications include the feed of biocides in open-air cooling
towers. The feed cycle is initiated and controlled by the programmable
timer. The Series T7 provides everything you need in one unique, compact
package to create a simple and cost effective metering system for timed
applications.
Principal of Operation
The Series T7 is controlled by a 7-day programmable timer. The timer is
programmable in 1-minute increments with up to 8 on/off cycles per day.
Each timed event can be set to run any day of the week on a 7-day cycle.
Other control features include a standby mode, continuous ‘ON’ mode and
the ability to adjust the stroke length from 0 – 100%.
Features
Isolated from Earth Ground
Mode Select Knob, Stroke Length
12, 22, 30 & 44 GPD @ 100 psi – 7 bar
Stroke length adjust 0-100%. Turn down ratio 10:1
7-Day Timer
Solid-state 7-day electronic timer for easy
adjustment of metering schedules and feed
rates. Manual control allows for easy priming
and start-up. The timer is programmable in 1
minute increments, with up to 8 events per
day.
Pressure and Flow Rate Capacity
LC13BA LC14BA LC64BA LC44BA
Capacity GPH 0.50 1.00 1.25 2.00
nominal GPD 12 24 30 48
(max.) LPH 1.9 3.8 4.7 7.6
Pressure PSIG 100 100 100 50
(max .) BAR 7 7 7 3.3
MODEL
Electronic Metering Pumps with Integrated
Controller
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Stroke Length Turn-Down Ratio:
10:1
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115 VAC; Amps:
0.6 Amps
@ 230 VAC; Amps:
0.3 Amps @ 230 VAC
Contact
factory for
applicable
agency
approvals.