Pressure and Flow Rate Capacity
LBC2 LB02 LBC3 LB03 LB04 LB64 LBC4 LBS2 LBS3 LBS4
Capacity GPH 0.25 0.25 0.42 0.50 1.00 1.25 2.00 0.50 1.38 2.42
nominal GPD 6 6 10 12 24 30 48 12 33 58
(max .) LPH 0.9 0.9 1.6 1.9 3.8 4.7 7.6 1.9 5.2 9.14
Pressure
1
GFPP, PVDF, 316SS
or PVC (W code)
w/TFE Seats) 250 (17) 250 (17)
(max .) PVC (V code) Viton or
CSPE Seats / Degas
Liquid End 150 (10) 150 (10)
Connections
Tubing
3/8" ID X 1/2" OD
Piping
Strokes/Minute
SPM
Note 1: Pumps with rated pressure above 150 PSI will be de-rated to 150 PSI Max. when selecting certain valve options, see Price Book for details.
1/4" FNPT
125 250
150 (10) 100 (7) 100 (7) 50 (3.3) 150 (10) 100 (7)
MODEL
PSIG
(Bar)
150 (10) 250 (17)
1/4" ID X 3/8" OD 1/4" ID X 3/8" OD
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS: 1
000 CPS
Stroke Frequency Max SPM:
125 / 250 by Model
Stroke Frequency Turn-Down Ratio:
10:1 / 100:1 by Model
Stroke Length Turn-Down Ratio:
10:1
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115 VAC; Amps:
0.6 Amps
@ 230 VAC; Amps:
0.3 Amps
Peak Input Power:
130 Watts
Average Input Power @ Max SPM:
50 Watts
Electronic Metering Pumps
Series A PLUS
Key Features
 Manual Control by on-line adjustable stroke rate and stroke length.
 Agency approved for demanding OUTDOOR and indoor applications.
 Highly Reliable timing circuit.
 Water Resistant excellent for OUTDOOR and indoor applications.
 Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
 Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
 Premium Standard Wetted Component Materials.
 Few Moving Parts and Wall Mountable.
 Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
 Optional Control:
External pace with auto/manual selection.
External stop function
1000:1 turndown control (S2, S3 & S4 sizes only)