Specifications

18
Series E-DC
Key Features
 Powered by 12 Volt DC..
 Manual Control by on-line adjustable stroke rate and stroke length.
 Agency approved for demanding OUTDOOR and indoor applications.
 Highly Reliable timing circuit.
 Water Resistant excellent for OUTDOOR and indoor applications.
 Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
 Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
 Premium Standard Wetted Component Materials.
 Few Moving Parts and Wall Mountable.
 Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
Pressure and Flow Rate Capacity
LS02 LS13 LS14 LS44
Capacity GPH 0.25 0.50 1.00 1.85
nominal GPD 6 12 24 44
(max.) LPH 0.9 1.9 3.8 7.0
Pressure PSIG 150 150 100 100
(max.) BAR 10 10 7 7
Connections
Piping
Tubing
MODEL
3/8" ID X 1/2" OD
1/4" ID X 3/8" OD
1/4" FNPT
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS:
LS02, 13:
300 CPS
LS14, 44:
1000 CPS
Stroke Frequency Max SPM:
125
Stroke Frequency Turn-Down Ratio:
10:1
Stroke Length Turn-Down Ratio:
10:1
Power Input:
12.6 VDC Nominal Range 11.8-14.0 VDC
Average Current Draw:
LS02, 13, 14 Amps:
4
.
0 Amps
LS44 Amps:
8.0 Amps
Peak Input Power:
LS02, 13, 14 Power:
138.6 Watts
LS44 Power:
189 Watts
Average Input Power @ Max SPM:
LS02, 13, 14 Power:
50.4 Watts
LS44 Power:
100.8 Watts
Electronic Metering Pumps
Contact
factory for
applicable
agency
approvals.