Specifications
18
Series E-DC
Key Features
Powered by 12 Volt DC..
Manual Control by on-line adjustable stroke rate and stroke length.
Agency approved for demanding OUTDOOR and indoor applications.
Highly Reliable timing circuit.
Water Resistant excellent for OUTDOOR and indoor applications.
Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
Premium Standard Wetted Component Materials.
Few Moving Parts and Wall Mountable.
Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
Pressure and Flow Rate Capacity
LS02 LS13 LS14 LS44
Capacity GPH 0.25 0.50 1.00 1.85
nominal GPD 6 12 24 44
(max.) LPH 0.9 1.9 3.8 7.0
Pressure PSIG 150 150 100 100
(max.) BAR 10 10 7 7
Connections
Piping
Tubing
MODEL
3/8" ID X 1/2" OD
1/4" ID X 3/8" OD
1/4" FNPT
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS:
LS02, 13:
300 CPS
LS14, 44:
1000 CPS
Stroke Frequency Max SPM:
125
Stroke Frequency Turn-Down Ratio:
10:1
Stroke Length Turn-Down Ratio:
10:1
Power Input:
12.6 VDC Nominal Range 11.8-14.0 VDC
Average Current Draw:
LS02, 13, 14 Amps:
4
.
0 Amps
LS44 Amps:
8.0 Amps
Peak Input Power:
LS02, 13, 14 Power:
138.6 Watts
LS44 Power:
189 Watts
Average Input Power @ Max SPM:
LS02, 13, 14 Power:
50.4 Watts
LS44 Power:
100.8 Watts
Electronic Metering Pumps
Contact
factory for
applicable
agency
approvals.