Specifications

16
Series E
Key Features
 Manual Control by on-line adjustable stroke rate and stroke length.
 Agency approved for demanding OUTDOOR and indoor applications.
 Highly Reliable timing circuit.
 Water Resistant excellent for OUTDOOR and indoor applications.
 Internally Dampened To Reduce Noise, very acceptable for house-
hold installations.
 Guided Ball Check Valve Systems, to reduce back flow and enhance
outstanding priming characteristics.
 Premium Standard Wetted Component Materials.
 Few Moving Parts and Wall Mountable.
 Safe & Easy Priming with durable leak-free bleed valve assembly
(standard).
Pressure and Flow Rate Capacity
LEK2 LE12 LE02 LE33 LE13 LE03 LEK3 LEF4 LE34 LE14 LEH4 LEG4 LE44 LEK5 LEH5 LEH6 LEK7 LEH7 LEJ7 LEH8
Capacity GPH 0.13 0.21 0.25 0.50 0.50 0.50 0.60 0.85 0.90 1.00 1.70 1.75 1.85 2.50 3.15 5.00 8.00 10.00 10.00 25.00
nominal GPD 3 5 6 121212142022244142446076120192240240600
(max .) LPH 0.5 0.8 0.9 1.9 1.9 1.9 2.3 3.2 3.4 3.8 6.4 6.6 7 9.5 11.9 18.9 30.3 37.9 37.9 94.6
Pressure PSIG 300 250 150 250 150 100 100 250 150 100 250 150 100 150 150 100 50 35 80 30
(max.) BAR 2117101710 7 7 1710 7 1710 7 1010 73.32.45.52
Connections
MODEL
Tubing
1/4" ID X 3/8" OD
3/8" ID X 1/2" OD
1/4" FNPT
1/2" FNPT
3/8" ID X 1/2" OD
1/2" ID X 3/4" OD (LPH8 ONLY)
1/4" FNPT
Piping
Engineering Data
Reproducibility:
+/- 3% at maximum capacity
Viscosity Max CPS:
For viscosity up to 3000 CPS, select connection size 3, 4, B
or C with 316SS ball material. Flow rate will determine
connection/ball size. Greater than 3000 CPS require spring
loaded ball checks. See Selection Guide for proper connec-
tion.
Stroke Frequency Max SPM:
125
Stroke Frequency Turn-Down Ratio:
10:1
Stroke Length Turn-Down Ratio:
10:1
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115VAC; Amps:
1.0 Amps
@ 230 VAC; Amps:
0.5 Amps
Peak Input Power:
300 Watts
Average Input Power @ Max SPM:
130 Watts
Electronic Metering Pumps