Specifications

12
Series MP
Key Features
 Automatic Control, Fully scalable 4-20mA current signal that can also be
calibrated to precisely match the current signal reading of the sending device.
 Manual Control allows for a combined 1000:1 turndown resulting in accurate
metering for critical applications.
 Flow Verification option is available on select sizes.
 Relay Output for computer interface or AC power allows for external control.
 Six-button Touch Pad Control with internationally recognized symbols for
simplified programming.
 Simple Prompts in plain language allow for easy-to-understand instructions for
programming. Available in three languages.
 Alarm Signals for signal loss, full count, circuit failure, pulse overflow and pulse
rate high. Liquid low level indicator capability is standard.
 Timed Sequences can be set for selected intervals and rate for repetitive
metering.
 Pulse Signals can be multiplied or divided by 1 to 999 allowing for pumps to
handle peak requirements.
 LCD, 3 line backlit multi-lingual display allows for easy reading and user-friendly
programming.
 Calibrated Flow Rate display with total volume pumped last day, month and
since last reset.
Pressure and Flow Rate Capacity
LMK2
LMB2
LMA2
LMD3
LMB3
LMA3
LMK3
LMF4
LMD4
LMB4
LMH4
LMG4
LME4
LMK5
LMH5
LMH6
LMK7
LMH7
LMH8
Capacity GPH 0.13
0.21 0.25 0.50 0.50 0.50 0.60 0.85 0.90 1.00 1.70 1.75 1.85 2.50 3.15 5.00 8.00 10.00 21.00
nominal GPD 3 5 6
12 12 12 14 20 22 24 41 42 44 60 76 120 192 240 504
(max.) LPH
0.5 0.8 0.9 1.9 1.9 1.9 2.3 3.2 3.4 3.8 6.4 6.6 7.0 9.5 11.9 18.9 30.
3 37.9 79.5
Pressure PSIG
300 250 150 250 150 100 100 250 150 100 250 150 100 150 150 100 50 35 20
(max.) BAR
21 17 10 17 10
7 7
17 10
7
17 10
7
10 10
7
3.3 2.4 1.3
Connections
Note: Flow Verification: Available on K3, B4 and E4 with connection code 1; H6, K7 and H7 with connection code H; 1/4” ID x 3/8” OD only .
1/4" FNPT
1/2" FNPT
1/2" ID X 3/4" OD (LPH8 ONLY)
FLOW VERIFICATION (See Note)
MODEL
Tubing
Piping
3/8" ID X 1/2" OD
1/4" ID X 3/8" OD
3/8" ID X 1/2" OD
1/4" FNPT
Electronic Metering Pumps
CM
CM
CM
CM
Engineering Data
Reproducibility:
+/- 2% at maximum capacity
Viscosity Max CPS:
For viscosity up to 3000 CPS, select connection size 3, 4, B or C with 316SS ball material.
Flow rate will determine connection/ball size. Greater than 3000 CPS require spring loaded
ball checks. See Selection Guide for proper connection.
Controls:
6-Station Membrane Switch
Status Display:
16-Position LCD Dot Matrix Backilght
LED Indicator Lights, Panel Mount:
Power On - Green
Pulsing - Green Flashing
Stop - Red
Stroke Frequency Max SPM:
125
External Stroke Frequency Control (Automatic):
4-20 mADC, 20-4 mADC External Pacing
Output Relay (Signal Level Option):
24 VDC, 10 mA
Output Relay (Power Option):
250 VAC, 50/60 HZ, 0.5A
Stroke Frequency Turn-Down Ratio:
100:1
Stroke Length Turn-Down Ratio:
10:1
Engineering Data
Power Input:
115 VAC/50-60 HZ/1 ph
230 VAC/50-60 HZ/1 ph
Average Current Draw:
@ 115 VAC; Amps:
1.0 Amps
@ 230 VAC; Amps:
0.5 Amps
Peak Input Power:
300 Watts
Average Input Power @ Max SPM:
130 Watts
sales@novatech-usa.com • www.novatech-usa.com