Specifications

10
520 = DG/5FV Five Function
Valve with De-Gas
With the DG/5FV you don’t have to give up the accuracy
and control of a solenoid metering pump in order to
pump gaseous solutions. Available in a variety of materi-
als and popular sizes, the DG/5FV is ready to tackle
most applications. Not only does the DG/5FV provide
degassing, it is packed with features that increase safety,
enhance performance and generally improves the con-
venience of operation.
FEATURES
 De-Gas – Bypass gasses and fluid during normal
pump operation. Allows for the constant removal of
gases that would otherwise “air bind” the pump.
 Back Pressure – Maintains output reproducibility and
allows metering into atmospheric discharge.
 Anti-Siphon – Prevents siphoning through the pump
when point of injection is lower than the pump or into
the suction line of another pump. Rated at total vacuum.
 Air Bleed – Used during priming to manually remove air from the pump head.
 Discharge Drain – Depressurize pump discharge line without loosening tubing or fittings. Protects the operator
from chemical exposure.
SPECIFICATIONS
Material Of Construction:
Valve Body Polyvinylidene Flouride (PVDF)
Diaphragm TFE faced CSPE
O-Rings Viton or CSPE
Hardware 18-8 Stainless Steel (Recessed)
Maximum Flow: 10 GPH (37.85 LPH)
Minimum Flow: 3 GPD (.47LPH)
Maximum Viscosity: 1000 CPS
MAX Pressure Ratings: Up to 250 psi (17 BAR)
Note: Degas/bypass volume is adjustable, typically 1-10% of pump output.
Connections: ¼” (0.635 cm) Male NPT
½” (1.27 cm) OD tubing
3/8” (0.95 cm) OD tubing
All ports (input, output & bypass) on the selected valve will be the same.
OPERATION
The functions are selected by setting two dual position selector knobs. The label on the back panel of the DG/5FV
identifies each function with selector knob positions.
The DG/5FV is compatible with most PULSAtron pumps. Connected to the existing discharge valve the GG/5FV is ca-
pable of handling a large output flow as well as viscous liquids. A return port located on the side body provides flow of
chemical back to the solution tank when in the degas, air bleed or drain discharge mode.
Selection Guide cont’d.
REAR VIEW FRONT VIEW