Troubleshooting guide

4
3. Equipment Inspection
When you receive your order, check all equipment for:
Completeness against the shipping document / purchase order
For any evidence of shipping damage.
Shortages or damage should be reported immediately to the carrier and your Pulsafeeder Representative.
4. Storage Instructions
The MPC can be successfully stored for extended periods. The key to this success is temperature and
humidity control.
4.1 Short Term (0 - 12 months)
The MPC should be stored in a temperature and humidity controlled environment. It is preferable to
keep the temperature constant in the range of -18 to 60 Celsius (0 to 140 Fahrenheit). The relative
humidity should be 0 to 90% non-condensing.
4.2 Long Term (12 months or more)
Storage of the MPC for periods of longer than twelve months is not recommended. If extended storage
is unavoidable the MPC should be stored in accordance with those conditions stipulated for Short Term
Storage. In addition, a porous bag of 85g (3 oz) silica gel or similar dessicant should be placed inside
the enclosure. The cover should be re-installed to seal the desiccant within the enclosure. The conduit
connections must be tightly capped.
Special note for long-term storage:
If AC input power has not been applied to the MPC for a period greater than 12 months, the controller
must be prepared for operation. The MPC should have AC power applied at the input for a period of 8
hours before placing pump into normal operation. Refer to Installation and Wiring section for AC
power connection instructions.