Troubleshooting guide

18
8.1.2 Volume Method
SET STROKE TO 50%
ENTER TO START
1. Manually adjust the stroke length of the pump to 50%
2. ** Fill your calibration column to the zero or starting point
3. Press the ENTER key
TIMER XX SEC
ENTER TO STOP
4. Allow the pump to run for any length of time you choose, dependent on flow rate, calibration column
size, process conditions, etc. The system will time out at a maximum of 300 seconds.
5. Press the ENTER key to stop the pump
ENTER VOLUME
VOL = XX.XXX
6. Use the UP and DOWN arrow keys and the ENTER key to input the volume pumped from the
calibration column (in gallons or liters, dependent on MPC setup).
7. Press ENTER to proceed
SET STROKE TO 100%
ENTER TO START
8. Manually adjust the stroke length of the pump to 100%
9. ** Fill your calibration column to the zero or starting point
10. Press the ENTER key
TIMER XX SEC
ENTER TO STOP
11. Allow the pump to run for any length of time you choose, dependent on flow rate, calibration column
size, process conditions, etc. The system will time out at a maximum of 300 seconds.
12. Press the ENTER key to stop the pump
ENTER VOLUME
VOL = XX.XXX
13. Use the UP and DOWN arrow keys and the ENTER key to input the volume pumped from the
calibration column (in gallons or liters, dependent on MPC setup).
14. Press ENTER to proceed
PUMP FLOW
CALIBRATED
15. Pump flow calibration is complete
16. Press the MENU key three times to exit back to the main operating screen.