Troubleshooting guide

9
72-001-02 Rev A
5. Equipment Startup
5.1 Check oil level
All pumps are supplied filled with oil. The prevent oil spills during shipping, a temporary plug is
provided. Before starting up the pump replace the temporary plug with the operational plug. Check the
oil level daily.
5.2 Fastener Inspection
All pump fasteners should be checked prior to pump operation, and occasionally during use. This
would include reagent head mounting bolts, motor mounting bolts, and the hardware that secures the
pump to its foundation. Most hardware can be checked simply to ensure it is not loose. However, when
checking reagent head bolt torque each bolt should be 44 lbf/inch.
5.3 Output Adjustment
All BLACKLINE
®
pumps have a hand wheel for manual stroke adjustment. The hand wheel can be
adjusted to any point from 0 to 100%. This value represents the stroke length setting and therefore the
flow rate of the pump relative to its maximum output.
5.3.1 Stroke Length Adjustment
The graduated knob from 0 to 10 rotates along a fixed linear vernier.
The line of the fixed vernier is the benchmark to set the adjustment
system at desired flow rate percentage value. One graduated knob
complete turn corresponds to an adjustment change from 1% to
100%.
Figure 4