10. TERMINALS AND WIRING
Type Bi-stable, quick-connect spring clamp terminals. IP20 Finger safe construction.
Suitable for field- and factory installation. Shipped in open position.
Solid wire 0.5-6mm
2
Stranded wire 0.5-4mm
2
American wire gauge 20-10 AWG
Ferrules Allowed, but not required
Wire stripping length 10mm / 0.4inch
Pull-out force 10AWG:80N, 12AWG:60N, 14AWG:50N, 16AWG:40N (according to UL486E)
Fig. 10-1 Connecting a wire
1.
Insert the wire
2.
Snap the lever
To disconnect wire: same procedure
vice versa
Instructions:
a) Use appropriate copper cables that are designed
for an operating temperature of:
60°C for ambient up to 45°C and
75°C for ambient up to 60°C minimum.
b) Follow national installation codes and
installation regulations!
c) Ensure that all strands of a stranded wire enter
the terminal connection!
d) Up to two stranded wires with the same cross
section are permitted in one connection point
(except PE wire).
e) Do not use the unit without PE connection.
11. EMC
The decoupling module is suitable for applications in industrial environment as well as in residential, commercial and
light industry environment without any restrictions. CE mark is in conformance with EMC guideline 89/336/EEC and
93/68/EEC and the low-voltage directive (LVD) 73/23/EWG. A detailed EMC Report is available upon request
EMC Immunity
EN 61000-6-1 EN 61000-6-2
Generic standards
Electrostatic discharge EN 61000-4-2 Contact discharge
Air discharge
8kV
15kV
Criterion A
Criterion A
Electromagnetic RF field EN 61000-4-3 80MHz-1GHz 10V/m Criterion A
Fast transients (Burst) EN 61000-4-4 Input
Output
2kV
2kV
Criterion A
Criterion A
Conducted disturbance EN 61000-4-6 0.15-80MHz 10V Criterion A
Criterions:
A: Device shows normal operation behavior within the defined limits.
EMC Emission
EN 61000-6-3 and EN 61000-6-4 Generic standards
Conducted emission EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 Class B, input lines
EN 55022 Class B, output lines
Radiated emission EN 55011, EN 55022 Class B
This device complies with FCC Part 15 rules.