Datasheet

UBC10.241, UBC10.241-N1
USeries
24V, 10A, DC-UPS
May. 2008 / Rev. 1.1 DS-UBC10.241-EN
All parameters are specified at an input voltage of 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time
unless otherwise noted. It is assumed that the input power source can deliver a sufficient output current.
www.pulspower.com Phone +49 89 9278 0 Germany
1/23
DC-UPS WITH INTEGRATED BATTERY
Compact and Easy to Install
Longest Buffer Time in Class
Easy Battery Access
Stable Output Voltage in Buffer Mode
Superior Battery Management for Longest Battery Life
Temperature Compensated Battery Charging
Comprehensive Diagnostics and Monitoring Functions
Replace Battery Signal Included
Electronically Overload and Short Circuit Protected
50% Power Reserves
Selectable Buffer Time Limiter
1. GENERAL DESCRIPTION
2. SHORT-FORM DATA
Input voltage nom. 24Vdc
range 22.5-30Vdc
Output current min. 15A Normal mode
min. 10A Buffer mode
Output voltage typ. 0.23V lower
as input voltage
Normal mode
22.25V Buffer mode, 10A
Integrated battery 12V 5Ah VRLA lead acid
Temperature range 0 to 40°C Operational
Dimensions 123x124x119mm WxHxD
Buffer time typ. 16’15” At 5A load
typ. 6’15” At 10A load
This uninterruptible power supply (UPS) controller
UBC10.241 with integrated battery is a compact
addition to standard 24V power supplies to bridge
power failures or voltage fluctuations. Expensive
downtimes, long restart cycles and loss of data can
be avoided.
The DC-UPS includes a professional battery
management system which charges and monitors
the battery to achieve the longest battery service life
as well as many diagnostic functions that ensure a
reliable operation of the entire system.
A unique feature of the UBC10.241 is that only one
12V battery is required to buffer the 24V output.
This makes matching batteries unnecessary and
allows a precise battery charging and testing.
The UBC10.241 has one integrated 12V 5Ah high
current VRLA battery, which is easy to change.
In addition to the UBC10.241, a separate UPS
controller (UB10.241) which requires an external 12V
battery is available when a longer buffer time is
required.
Typical setup of a DC-UPS system with the UBC10.241:
24V
Power
Supply
UBC10.241
24V
DC-UPS
AC
e.g.:
Dimension
DC
24V
Load
e.g.: PLC
3. ORDER NUMBERS
4. MARKINGS
DC-UPS
UBC10.241
Standard unit
UBC10.241-N1
Battery not assembled
Accessories UZB12.051
Battery 12V 5Ah
IND. CONT. E
Q.
UL 508
UL 60950-1
Class I Div 2
R
182790
CUS
GL
Marine
EMC, LVD