Datasheet

Your partner in power supply:
European
Power Supply
Manufacturers
Association
PULS GmbH
Arabellastraße 15
D-81925 München
Tel.: +49 89 9278-0
www.puls-power.com
Fax: +49 89 9278-199
Data sheet
2/2 sl20e100 / 050923
Bayerns Best 50
Czech 100 Best
Europe’s 500
Functional diagrams
Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice.
All data is valid for SL20.100. Regarding the SL20.101 (including PFC) some values may differ.
Start / Overload Behaviour
Startup delay typ. 0.5s
Rise time ca. 20-80ms, depending on load
Duration of switch-on attempts at
Initial application
on mains
Subsequent attempts
ca. 1.4s
ca. 0.5s
Hiccup operation at V
out
< ca. 14V
Duration between switch-on at-
tempts
ca. 4s
Electronic current limiting, protects against overload and short circuit:
•V
out
< ca. 14V: Periodical switch-on attempts (hiccup-mode).
Advantages of the switch-on/overload behaviour:
Safer switch-on into highly non-linear loads with large
starting currents
Short-term overloads result in current limiting and not in
an immediate shut-down.
Parallel operation of several units possible.
Proper switch-on performance is obtained.
0
20
40
60
80
100
185 205 225 245 265
Input voltage VACin [V]
Hold-up time [ms]
40% Load
60% Load
80% Load
100% Load
125% Load
84
85
86
87
88
89
90
91
92
93
94
95
5 10152025
Output current Iout [A]
Efficiency [%]
184V AC
230V AC
264 V AC
0
8
16
24
32
0 5 10 15 20 25 30 35 40
Output current Iout [A]
Output voltage Vout [V]
24V / Single
24V / Parallel
28V /Single
28V / Parallel
Vout < ca. 14V: Hiccup mode
Output characteristic (typ.) Efficiency (typ., at V
out
=24V)
Hold-up time (min., at V
out
=24V)
Further information
For further information, especially about
•EMC
Connections
•Safety, Approvals
Mechanics und Mounting,
see page 2 of the „The SilverLine“ data sheet
For detailed dimensions
see SilverLine mechanics data sheet SL20