Datasheet

QS5.241, QS5.241-A1
Q-Series
24V, 5A, SINGLE PHASE INPUT
13. FRONT SIDE AND USER ELEMENTS
Fig. 13-1 Front side
A
Input Terminals (Quick-connect spring-clamp terminals)
N, L Line input
PE (Protective Earth) input
B
Output Terminals (Quick-connect spring-clamp terminals, two pins per pole)
+ Positive output
Negative (return) output
C
DC-OK Relay Contact (Quick-connect spring-clamp terminals)
The DC-OK relay contact is synchronized with the DC-OK LED.
See chapter 8 for details.
D Output voltage potentiometer
Multi turn potentiometer;
Open the flap to adjust the output voltage. Factory set: 24.1V
E DC-OK LED (green)
On, when the output voltage is >90% of the adjusted output voltage
F Overload LED (red)
On, when the voltage on the output terminals is <90% of the adjusted output voltage,
or in case of a short circuit in the output.
Input voltage is required
Flashing, when the unit has switched off due to over-temperature.
Indicators, LEDs
Overload LED DC-OK LED DC-OK Contact
Normal mode OFF ON Closed
During BonusPower
®
OFF ON Closed
Overload (VOUT < 90%) ON OFF Open
Output short circuit ON OFF Open
Temperature Shut-down Intermitted OFF Open
No input power OFF OFF Open
Nov. 2011 / Rev. 2.1 DS-QS5.241-EN
All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
12/26