Datasheet
QS10.301
Q-Series
30V, 8A, SINGLE PHASE INPUT
6. OUTPUT
Output voltage nom. 30V
Adjustment range min. 28-32V guaranteed
max. 35V
***)
at clockwise end position of potentiometer
Factory setting typ. 30.0V ±0.2%, at full load, cold unit
Line regulation max. 10mV 60-300Vac
Load regulation max. 100mV static value, 0A Æ 8A
Ripple and noise voltage max. 50mVpp 20Hz to 20MHz, 50Ohm
Output current nom. 8.6A continuously available at 28V, see Fig. 6-1
nom. 8A continuously available at 30V, see Fig. 6-1
nom. 7.5A continuously available at 32V, see Fig. 6-1
nom. 12.8A
*)
short term available BonusPower
® *)
,
at 28V, for typical 4s, see Fig. 6-1
nom. 12A
*)
short term available BonusPower
® *)
,
at 30V, for typical 4s, see Fig. 6-1
nom. 11.3A
*)
short term available BonusPower
® *)
,
at 32V, for typical 4s, see Fig. 6-1
Output power nom. 240W continuously available
nom. 360W
*)
short term available BonusPower
® *)
BonusPower
®
time typ. 4s duration until the output voltage dips, see Fig. 6-2
min. 3s
max. 5s
BonusPower
®
recovery time typ. 7s overload free time to reset power manager, see Fig. 6-3
Overload behaviour cont. current
Short-circuit current min. 5.8A
**)
continuous, load impedance 100mOhm, see Fig. 6-1
max. 8.7A
**)
continuous, load impedance 100mOhm, see Fig. 6-1
min. 16A
**)
during BonusPower
® *)
, load impedance 100mOhm
max. 22A
**)
during BonusPower
® *)
, load impedance 100mOhm
Output capacitance typ. 7 000μF included inside the power supply
*) BonusPower®, short term power capability (up to typ. 4s)
The power supply is designed to support loads with a higher short-term power requirement without damage or shutdown. The short-
term duration is hardware controlled by an output power manager. This BonusPower
®
is repeatedly available. Detailed information
can be found in chapter 22.1. If the power supply is loaded longer with the BonusPower
®
than shown in the Bonus-time diagram (see
Fig. 6-2), the max. output power is automatically reduced to 240W.
**) Discharge current of output capacitors is not included.
***) This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not
guaranteed value which can be achieved. The typical value is about 33.2V.
Peak current capability (up to several milliseconds)
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start
current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be
discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 22.2.
Peak current voltage dips typ. from 30V to 26V at 16A for 50ms, resistive load
typ. from 30V to 25V at 32A for 2ms, resistive load
typ. from 30V to 22V at 32A for 5ms, resistive load
Dec. 2014 / Rev. 2.2 DS-QS10.301-EN
All parameters are specified at 30V, 8A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/26