9. EMC
This redundancy module is suitable for applications in industrial environment as well as in residential, commercial and
light industry environment without any restrictions (e.g. cable length). The CE mark indicates conformance with EMC
directive 2004/108/EC and the low-voltage directive (LVD) 2006/95/EC.
A detailed EMC report is available on request.
EMC Immunity
According generic standards: EN 61000-6-1 and EN 61000-6-2
Electrostatic discharge EN 61000-4-2 Contact discharge
Air discharge
8kV
15kV
Criterion A
Criterion A
Electromagnetic RF field EN 61000-4-3 80MHz-2.7GHz 10V/m Criterion A
Fast transients (Burst) EN 61000-4-4 Input lines
Output lines
2kV
2kV
Criterion A
Criterion A
Surge voltage on input lines EN 61000-4-5 + Æ - 200V Criterion A
Surge voltage on output line EN 61000-4-5 + Æ - 200V Criterion A
Conducted disturbance EN 61000-4-6 0.15-80MHz 10V Criterion A
Power-frequency magnetic
field *)
EN 61000-4-8 50Hz 30A/m Criterion A
Criterions:
A: Redundancy module shows normal operation behavior within the defined limits.
Notes:
*) A test is not applicable according to EN 61000-6-2, since the device does not contain components susceptible to magnetic fields, e.g. hall
elements, electrodynamic microphones, etc.
EMC Emission
According generic standards: EN 61000-6-3 and EN 61000-6-4
Conducted emission IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 Class B, input lines *)
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1 Class B, output lines *)
Radiated emission EN 55011, EN 55022 Class B
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
*) Provided, that power sources connected on the inputs fulfill the class B requirements too.
Oct. 2010 / Rev. 1.0 DS-MLY02.100-EN
All parameters are specified at 24V, 10A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted
www.pulspower.com Phone +49 89 9278 0 Germany