Datasheet

ML50.100, ML50.109
MiniLine
24V, 2.1A, SINGLE PHASE INPUT
Mar. 2007 / Rev. 1.0 DS-ML50.100-EN
All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
8/20
12. FUNCTIONAL DIAGRAM
Fig. 12-1 Functional diagram
Input Fuse
&
Input Filter
L
N
Output Over-
Voltage
Protection
DC-OK
Transistor
Signal
Input
Rectifier
&
Inrush
Limiter
Power
Converter
Output
Voltage
Regulator
+
+
-
-
Output
Filter
V
OUT
DC
ok
DC-ok
Signal
13. RELIABILITY
These units are extremely reliable and use only the highest quality materials. The number of critical components such
as electrolytic capacitors has been reduced.
AC 100V AC 120V AC 230V
Lifetime expectancy min. 34 000h 44 000h 54 000h 40°C, 24V, 2.1A
min. 112 000h 117 000h 111 000h 40°C, 24V, 1.05A
min. 96 000h 125 000h 152 000h 25°C, 24V, 2.1A
MTBF SN 29500, IEC 61709 2 383 000h 2 456 000h 2 613 000h 40°C, 24V, 2.1A
3 977 000h 4 100 000h 4 362 000h 25°C, 24V, 2.1A
MTBF MIL HDBK 217F 1 021 000h 1 053 000h 1 120 000h 40°C, 24V, 2.1A, Ground Benign GB40
1 370 000h 1 413 000h 1 503 000h 25°C, 24V, 2.1A, Ground Benign GB25
The Lifetime expectancy shown in the table indicates the operating hours (service life) and is determined by the
lifetime expectancy of the built-in electrolytic capacitors.
Lifetime expectancy is specified in operational hours. Lifetime expectancy is calculated according to the capacitor’s
manufacturer specification. The prediction model allows a calculation of up to 15 years from date of shipment.
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates
reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily
represent the life of a product.