Datasheet

X Input
Input voltage AC 100-120/220-240V (Auto Select), 47...63 Hz
(AC 85...132V / AC 184...264V,
DC 220...375V N= + and L= - )
Input current <2.1A (@ AC 100V
in
, 100W P
out
)
<1A (@ AC 220V
in
, 100W P
out
)
External fusing not required, unit provides internal fuse
(T3A15H, not accessible)
Transient immunity Transient resistance acc. to VDE 0160 / W2
(750V/ 1.3 ms), over entire load range
Hold-up time
(see diagram below)
>40 ms @ AC 230V, 24.5V / 4.2A
>20 ms @ AC 196V, 24.5V / 4.2A
>20 ms @ AC 100V, 24.5V / 4.2A
X Efficiency, Reliability
Efficiency
Losses
typ. 90% (AC 230V, 24.5V / 4.2A)
(see also diagram below)
typ. 11.4W (AC 230V, 24.5V / 4.2A)
MTBF (Reliability) appr. 500.000 h acc. to Siemensnorm SN 29500
(24.5V / 4.2A, AC 230V, T
amb
= +40 °C)
Prior to shipment, every unit undergoes the following tests in order to
isolate any defective units which might suffer an early failure:
Run-in / burn-in (Full load, T
amb
= +60°C, on/off cycle)
Functional test (100 %)
X Construction, Mechanics, Installation
Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid
on three housing sides to keep out small parts (e.g. screws), IP20
Dimensions and weight
W x H x D
•Weight
73 mm x 75 mm x 103 mm (+ DIN rail)
Depth incl. terminals: 98 mm (+ DIN rail)
360 g
Mounting orientation ,
or (cf. ’Output’)
Ventilation/Cooling
Free space f. cooling
Normal convection, no fan required
recom'd.: 25 mm on sides with ventilation grid
Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15).
Unit sits safely and firmly on the rail; no tools required even to remove
Connection by Spring Clamp terminals; uniformly firm hold,
vibration-resistant and maintenance-free:
2 terminals per output
Connector size range
flexible cable
solid cable
Wire strip length
0.3-2.5mm
2
(28-12 AWG)
0.3-4mm
2
(28-12 AWG)
Ferrules admissible
6mm (0.24in) recommended
Design details – for your advantage:
All terminals are easy to reach as mounted on the front panel.
Input and output are strictly apart from each other (input below, out-
put above) and so cannot be mixed up.
Mounting and connection do not require any screwdriver
Easy, quick, durable and reliable installation.
X Diagrams
0
5
10
15
20
25
30
35
012345678
Output current Iout [A]
Output voltage Vout [V]
Vin = AC 115/230V
'Single Use'
Vin = AC 115/230V
'Parallel Use'
0
20
40
60
80
100
120
-10 0 10 20 30 40 50 60 70
Ambient temperature [°C]
Output power [W]
0
20
40
60
80
100
120
140
160
80 120 160 200 240 280
Input voltage VACin [V]
Hold-up time [ms]
Pout=100W, typ.
Pout=100W, min.
Pout=50W, typ.
Pout=50W, min.
83
84
85
86
87
88
89
90
91
11,41,82,22,633,43,84,2
Output current Iout [A]
Efficiency [%]
11 5 V AC in
23 0 V AC in
Output characteristic V
out
/I
out
(min.)
Efficiency
Hold-up time with ACin
(@ V
out
= 24.5V, typ.)
(at V
out
= 24.5V, typ. + min.)
Derating
of output power
Mounting
85-132 V ACin A-a A-b A-b
185-264 V ACin A-a A-b A-b
220-375 V DCin A-a A-b A-b
a
b
A
X Output
Output voltage
preset
DC 24-28V (adj. by front panel potentiometer)
24.5V ± 0.5% @ 4.2A
Voltage regulation stat. <1% V
out
(Jumper in pos. 'Single Use')
stat. <3% V
out
(Jumper in pos. 'Parallel Use'),
dyn. ±1.5% V
out
over all
Ripple/Noise <50mV
PP
(20 MHz bandw., 50 measurem.)
Overvoltage prot. (OVP) <36V
Output noise
suppression
EMI values below EN 61000-6-3, even when using
long (>2m), unscreened output cables
Rated continuous
loading
up to 4.2A @ 24.5V / 3.6A @ 28V (convection cool-
ing), depending on built-in orientation,
V
in
and T
amb
For details see derating diagram below
Overload behaviour PULS Overload Design™: No switch-off at
overload/short-circuit, instead: up to 1.9 I
rated.
So you need no oversizing to start awkward
loads.
Protection Unit is protected against (also permanent) short-
circuit, overload and open-circuit.
Derating depending on built-in orientation;
see diagram below
Parallel operation yes (selectable by front panel jumper)
Power back immunity 35V
Operating indicator Green LED
X Environmental Data, EMC, Safety
Ambient temperature range (measured 25 mm below unit)
storage/transport
operation
-25°C ... +85°C
-10°C ... +70°C (for derating see diagram below)
Humidity max. 95% (without condensation)
Electromagnetic
emissions (EME)
EN 61000-6-3 (includes EN 61000-6-4)
Class B (EN 55011, EN 55022) incl. output noise
suppression
EN 61000-3-2 (PFC)
Electromagnetic
immunity (EMI)
EN 61000-6-2 (includes EN 61000-6-1)
Safe low voltage:
Prot. class/degree:
SELV (EN 60950, VDE0100/T.410), PELV (EN 50178)
Class 1 (EN 60950) / IP20 (EN 60529)
The PSU complies with all major safety approvals for EU (EN 60 950,
EN 60204-1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865),
Canada (CAN/CSA-C22.2 No 60950 [CUR], CAN/CSA-C22.2 No. 14 [CUL]), CB
Scheme (IEC 60950). Hazardous Location Class I Div. 2 (UL 1604)
Technical Data ML100.100
Product information (ML100e100), Rev.: 29. June 2004. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They