User manual
CD5.241, CD5.241-S1
CD–Series
DC/DC Converter; 24V, 5A
Jan. 08 / Rev. 1.1 DS-CD5.241-EN / All parameters are specified at 24V, 5A and 24Vdc input at 25°C ambient unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
10/22
14. DC-OK RELAY CONTACT (CD5.241-S1)
This feature is only available on the model CD5.241-S1 and monitors the output voltage, which is produced by the
DC/DC converter itself. It is independent of a back-fed voltage from a unit which is connected in parallel to the DC/DC
converter output. It is a “Normally Open” contact.
Contact closes As soon as the output voltage reaches the adjusted output voltage.
Contact opens As soon as the output voltage dips more than 10% below the adjusted output voltage.
Short dips will be extended to a signal length of 250ms. Dips shorter than 1ms will be ignored.
Contact re-closes As soon as the output voltage exceeds 90% of the adjusted voltage.
Contact ratings max 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A Resistive load
min 1mA at 5Vdc Minimum permissible load
Isolation voltage See dielectric strength table in section 20
Fig. 14-1 DC-ok relay contact behavior
250ms
90%
V
ADJ
<
1ms
10%
open
V
OUT
=
V
ADJ
openclosed closed
>
1ms
Note:
The DC-ok feature requires that the output voltage
reaches the nominal (=adjusted) level after turn-on in
order to function according to specification. If this level
cannot be achieved, the overload lamp will be on and
the DC-ok contact will be open. The overload signal will
only shut off as soon as the adjusted voltage is reached.
This is an important condition to consider particularly, if
the load is a battery, the DC/DC converter is used in
parallel or the DC/DC converter is used for N+1
redundant systems.
15. INPUT-LOW RELAY CONTACT (CD5.241-S1)
This feature monitors the input voltage of the DC/DC converter. It is a “Normally Closed” contact.
Contact is closed
When the input voltage falls below 19.5Vdc (typ.)
Contact opens
As soon as the input voltage reaches 20.5 Vdc (typ.)
Contact ratings max 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A Resistive load
min 1mA at 5Vdc Minimum permissible load
Isolation voltage See dielectric strength table in section 20