Datasheet
CD5.241-S1
CD-Series 
DC/DC Converter 24V, 5A 
5.  OUTPUT 
Output voltage  nom.  24V   
Adjustment range  min.  23-28V  guaranteed 
  max.  30V  at clockwise end position of potentiometer 
Factory setting    24.1V   ±0.2%, at full load, cold unit 
Line regulation  max.  25mV  Input voltage variations between 18 to 32.4Vdc 
Load regulation  max.  150mV  static value, 0A Æ 5A 
Ripple and noise voltage  max.  50mVpp  20Hz to 20MHz, 50Ohm 
Output capacitance  typ.  2 200μF   
Output current  nom.  6A  at 24V, ambient < 45°C, see Fig. 5-1 
  nom.  5A  at 24V, ambient < 60°C, see Fig. 5-1 
  nom.  5.2A  at 28V, ambient < 45°C, see Fig. 5-1
  nom.  4.3A  at 28V, ambient < 60°C, see Fig. 5-1
Output power  nom.  144W  for ambient temperatures < 45°C 
  nom.  120W  for ambient temperatures < 60°C 
Short-circuit current  min.  7A  continuous current, short circuit impedance 200mOhm 
 max. 10A continuous current, short circuit impedance 200mOhm 
Fig. 5-1 Output voltage vs. output current at 
24Vdc input voltage, typ. 
Fig. 5-2 Current limitation vs. input voltage, 
(23V constant voltage load), typ. 
Output Voltage
0
048
4
8
12
28V
16
20
24
12
A
1062
Adjustment
Range
Output Current
Output Current
5.8
15 21 27
5.9
6.0
6.1
6.6A
6.3
6.4
6.5
33Vd
c
302418
6.2
Input Voltage
Peak current capability (up to several milliseconds) 
The DC/DC converter can deliver a peak current, which is higher than the specified short term current. This helps to 
start current demanding loads or to safely operate subsequent circuit breakers. 
The extra current is supplied by the output capacitors inside the DC/DC converter. During this event, the capacitors will 
be discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 24.1. 
Peak current voltage dips  typ.  from 24V to 18V  at 10A for 50ms, resistive load 
  typ.  from 24V to 15V  at 20A for 2ms, resistive load 
  typ.  from 24V to 11.5V  at 20A for 5ms, resistive load 
Oct 2009 / Rev. 1.3 DS-CD5.241-S1-EN 
All parameters are specified at 24V, 5A, 24Vdc input voltage, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com Phone +49 89 9278 0 Germany 