8. EFFICIENCY AND POWER LOSSES
Efficiency typ. 90.2% at 230Vac, 24V, 5A
typ. 90.0% at 230Vac, 24V, 6A (Power Boost)
Average efficiency
*)
typ.
88.2%
25% at 1.25A, 25% at 2.5A,
25% at 3.75A. 25% at 5A
Power losses typ. 1.2W at 230Vac, 24V, 0A
typ. 7.7W at 230Vac, 24V, 2.5A
typ. 13.2W at 230Vac, 24V, 5A
typ. 16.1W at 230Vac, 24V, 6A (Power Boost)
*) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25%
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100%
of the nominal load for the rest of the time.
Fig. 8-1 Efficiency vs. output current at 24V,
typ
Fig. 8-2 Losses vs. output current at 24V, typ.
Efficiency
1
86
88
90
85
91%
6A245
Output Current
3
87
89
Power Losses
012 456A
0
3
9
15
18W
6
3
12
Output Current
Fig. 8-3 Efficiency vs. input voltage at 24V,
5A, typ.
Fig. 8-4 Losses vs. input voltage at 24V, 5A,
typ.
Efficiency
170 190
210
230 250 270Vac
88
89
90
Input Voltage
91%
Power Losses
0
3
6
9
12
15
18W
170 190
210
230 250 270Vac
Input Voltage