User manual
CS5.241, CS5.241-C1, CS5.241-S1
C–Series
24V, 5A, SINGLE PHASE INPUT
Dec. 2006 / Rev. 1.3 DS-CS5.241-EN
All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
11/20
15. ENVIRONMENT
Operational temperature -25°C to +70°C (-13°F to 158°F) reduce output power according
Fig. 15-1
Output de-rating 1.6W/°C 45-60°C (113°F to 140°F),
3W/°C 60-70°C (140°F to 158°F),
Storage temperature -40 to +85°C (-40°F to 185°F) storage and transportation
Humidity 5 to 95% r.H. IEC 60068-2-30
Do not energize while condensation is present
Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g
2 hours / axis
IEC 60068-2-6
Shock 30g 6ms, 20g 11ms
3 bumps / direction, 18 bumps in total
IEC 60068-2-27
Altitude 0 to 6000m (0 to 20 000ft) Reduce output power or ambient
temperature above 2000m sea level.
Output de-rating (for altitude) 7.5W/1000m or 5°C/1000m above 2000m (6500ft), see Fig. 15-2
Over-voltage category III EN 50178, altitudes up to 2000m
II Altitudes from 2000m to 6000m
Degree of pollution 2 EN 50178, not conductive
Fig. 15-1 Output current vs. ambient temp., Fig. 15-2 Output current vs. altitude, 24V
0
-25 0 20 40
70°
C
1
2
3
4
5
6A
60
Ambient Temperature
c
o
n
t
i
n
u
o
u
s
s
h
o
r
t
t
e
r
m
Allowable Output
Current at 24V
0
0 2000 4000
6000m
1
2
3
4
5
6A
Altitude
A
.
.
.
T
a
m
b
<
6
0
°
C
B
.
.
.
T
a
m
b
<
5
0
°
C
C
.
.
.
T
a
m
b
<
4
0
°
C
C
B
A
s
h
o
r
t
t
e
r
m
Allowable Output
Current at 24V
The ambient temperature is defined 2cm below the unit.
16. PROTECTION FEATURES
Output protection Electronically protected against overload, no-load and short-circuits
Output over-voltage protection typ. 35Vdc
max. 39Vdc
In case of an internal power supply defect, a redundant
circuitry limits the maximum output voltage. The output
shuts down and automatically attempts to restart.
Output over-current protection electronically limited see Fig. 8-1
Degree of protection IP 20 EN/IEC 60529
Penetration protection > 3.5mm e.g. screws, small parts
Over-temperature protection yes output shut-down with automatic restart
Input transient protection MOV Metal Oxide Varistor
Internal input fuse T4A H.B.C. not user replaceable
Note: In case of a protection event, audible noise may occur.