Datasheet

CS10.244
C-Line
24V, 10A, SINGLE PHASE INPUT
4. DC-INPUT
Do not operate this power supply with DC-input voltage. Use the QS10.241 or CP10.241 unit instead.
5. INPUT INRUSH CURRENT
A NTC inrush limitation circuit limits the input inrush current after turn-on of the input voltage.
The charging current into the EMI suppression capacitors is disregarded in the first microseconds after switch-on.
Inrush current max. 59A
peak
at 230Vac, +40°C ambient, cold start
typ. 48A
peak
at 230Vac, +40°C ambient, cold start
Inrush energy max. 3A
2
s at 230Vac, +40°C ambient, cold start
Fig. 5-1 Typical input inrush current behavior
Input: 230Vac
Output: 24V, 10A
Ambient: +40°C
Upper curve: Input current (20A / DIV)
Medium curve: Input voltage (200V / DIV)
Lower curve: Output voltage (10V / DIV)
Time scale: 20ms / DIV
1 >
2 >
3
3 >
Jul. 2015 / Rev. 2.0 DS-CS10.244-EN
All parameters are specified at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/24