Datasheet

CPS20.241, CPS20.241-A1
C-Series
24V, 20A, SINGLE PHASE INPUT
Switching Frequencies
The power supply has two converters with two different switching frequencies included.
Switching frequency 1 80kHz to 130kHz PFC converter, input voltage and output power dependent
Switching frequency 2 80kHz to 95kHz Main converter, output power dependent
15. ENVIRONMENT
Operational temperature
*) -25°C to +70°C (-13°F to 158°F) reduce output power according Fig. 15-1
Storage temperature -40 to +85°C (-40°F to 185°F) for storage and transportation
Output de-rating 12W/°C 60-70°C (140°F to 158°F)
Humidity
**) 5 to 95% r.H. IEC 60068-2-30
Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g
2 hours / axis
IEC 60068-2-6
Shock 30g 6ms, 20g 11ms
3 bumps / direction, 18 bumps in total
IEC 60068-2-27
Altitude 0 to 2000m (0 to 6 560ft) without any restrictions
2000 to 6000m (6 560 to 20 000ft) reduce output power or ambient temperature,
see Fig. 15-2
IEC 62103, EN 50178, overvoltage category II
Altitude de-rating 30W/1000m or 5°C/1000m > 2000m (6500ft), see Fig. 15-2
Over-voltage category III IEC 62103, EN 50178, altitudes up to 2000m
II altitudes from 2000m to 6000m
Degree of pollution 2 IEC 62103, EN 50178, not conductive
*) Operational temperature is the same as the ambient temperature and is defined as the air temperature 2cm below the unit.
**) Do not energize while condensation is present
Fig. 15-1 Output current vs. ambient temp. Fig. 15-2 Output current vs. altitude
Allowed Output Current at 24V
0
-25 0 20 40
70°C
4A
8A
12A
16A
20A
24A
60
short term
A...100 to 264Vac, continuous
B... 85Vac, continuous
B A
Ambient Temperature
0
0 2000m 4000m
6000m
4A
8A
12A
16A
20A
24A
A
.
.
.
T
a
m
b
<
6
0
°
C
B
.
.
.
T
a
m
b
<
5
0
°
C
C
.
.
.
T
a
m
b
<
4
0
°
C
B
A
C
short term
Allowable Output Current at 24V
Altitude
See chapter AC-Input for de-rating requirements for input voltages between 85Vac and 100Vac.
May 2012 / Rev. 1.0 DS-CPS20.241-EN
All parameters are specified at 24V, 20A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
14/25