13. L
IFETIME
E
XPECTANCY
The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by
the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and
is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors
only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated
theoretical lifetime which can be used to compare devices.
AC 100V AC 120V AC 230V
Lifetime expectancy
284 000h 297 000h 294 000h At 12V, 5A and 40°C
804 000h 839 000h 833 000h At 12V, 5A and 25°C
88 000h 94 000h 110 000h At 12V, 10A and 40°C
248 000h 267 000h 311 000h At 12V, 10A and 25°C
44 000h 51 000h 61 000h At 12V, 12A and 40°C
126 000h 143 000h 171 000h At 12V, 12A and 25°C
14. MTBF
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates
reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily
represent the life of a product.
The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h
means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not
be determined if the failed unit has been running for 50 000h or only for 100h.
For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value.
AC 100V AC 120V AC 230V
MTBF
SN 29500, IEC 61709 682 000h 687 000h 732 000h At 12V, 10A and 40°C
1 212 000h 1 221 000h 1 294 000h At 12V, 10A and 25°C
MTBF
MIL HDBK 217F 287 000h 290 000h 308 000h
At 12V, 10A and 40°C;
Ground Benign GB40
417 000h 421 000h 447 000h
At 12V, 10A and 25°C;
Ground Benign GB25
68 000h 69 000h 73 000h
At 12V, 10A and 40°C;
Ground Fixed GF40
91 000h 93 000h 99 000h
At 12V, 10A and 25°C;
Ground Fixed GF25