Datasheet
CP20.241, CP20.241-C1, CP20.241-S1,
CP20.241-S2, CP20.241-V1, CP20.242
CP-Series
24V, 20A, 480W, SINGLE PHASE
Sep. 2018 / Rev. 1.0 DS-CP20.241-EN - All parameters are typical values specified at 230Vac, 50Hz input voltage, 24V, 20A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
2) At heavy overloads (when output voltage falls below 13V), the power supply delivers continuous output current for 2s. After this, the
output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the overload
exists. If the overload has been cleared, the device will operate normally. See Fig. 6-3.
Fig. 6-1 Output voltage vs. output current,
typ.
Fig. 6-2 Output voltage in “parallel use”
mode, typ.
Output Voltage
(Single Use, typ.)
0
4
8
12
28V
16
20
24
025
9/32
40A155 10 20 30 35
Adjustment
Range
Output Current
A: continuous current
B: intermitted current
A
B
Output Voltage
(Parallel Use, typ.)
22V
0816
23V
24V
25V
29V
26V
27V
28V
24A20124
Adjustment
Range
Factory
setting
Output Current
Fig. 6-3 Short-circuit on output, Hiccup
PLUS®
mode, typ. Fig. 6-4 Dynamic overcurrent capability, typ.
Output
Current
0
29A
18s
18s
18s
2s
2s
2s
t
Short -circuit
Normal
operation
Normal
operation
Output Voltage
(dynamic behavior, < 12ms)
0
0
4
8
12
28V
16
20
24
70A3010 40 5020 60
Adjustment
Range
Output Current