10. EFFICIENCY AND POWER LOSSES
AC 100V AC 120V AC 230V
Efficiency Typ. 93.6% 94.2% 95.6% At 24V, 20A
Typ. 93.5% 94.1% 95.5% At 24V, 24A (Power Boost)
Average efficiency
*)
Typ. 93.2% 93.8% 95.0% 25% at 5A, 25% at 10A,
25% at 15A. 25% at 20A
Power losses typ. 0.4W 0.5W 0.9W CP20.241-V1 in “Remote OFF”
mode
Typ. 2.5W 2.2W 2.2W At 24V, 0A
Typ. 16.0W 15.0W 12.5W At 24V, 10A
Typ. 32.8W 29.6W 22.1W At 24V, 20A
Typ. 40.0W 36.1W 27.1W At 24V, 24A (Power Boost)
*) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25%
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100%
of the nominal load for the rest of the time.
Fig. 10-1 Efficiency vs. output current at 24V,
typ
Fig. 10-2 Losses vs. output current at 24V,
typ.
Efficiency
12/32
4 6 8 101214 1820 24A
87
88
90
91
92
93
94
95
96%
Output Current
16 22
(
a
)
(
b
)
(
c
)
(a) 100Vac
(b) 120Vac
(c) 230Vac
Power Losses
0 2 6 8 12 14 24A
5
10
20
30
0
40W
18 204 10 16
Output Current
(
a
)
(
b
)
(
c
)
(a) 100Vac
(b) 120Vac
(c) 230Vac
35
25
15
22
Fig. 10-3 Efficiency vs. input voltage at 24V,
20A, typ.
Fig. 10-4 Losses vs. input voltage at 24V, 20A,
typ.
Efficiency
Power Losses
120 180 230 264Vac
90
91
92
93
Input Voltage
94
95
96%
120 180 230 264Vac
10
15
20
25
Input Voltage
30
35
40W
100
100