3. DC-INPUT
The input can be powered from batteries or similar DC sources and must be a PELV or SELV source or an "Isolated
Secondary Circuit" in order to maintain a SELV or PELV output.
Check for correct input polarity. The device will not operate when the voltage is reversed.
DC input Nom. DC 48V ±25%
DC input range Min. 36-60Vdc Continuous operation
Allowed voltage between input
and earth/ground
Max. 60Vdc or
42.2Vac
Continuous operation, according to IEC 62477-1
Allowed input ripple voltage Max. 10Vpp In the frequency range from 47 to 500Hz, the
momentary input voltage must always be within the
specified limits.
Turn-on voltage Typ. 35Vdc Steady-state value, see Fig. 3-1
Shut-down voltage Typ. 31Vdc Steady-state value, see Fig. 3-1
Input current Typ. 5.3A At 48Vdc input and 48V, 5A output load, see Fig. 3-3
Typ. 7.0A At 36Vdc input and 48V, 5A output load, see Fig. 3-3
Start-up delay Typ. 350ms See Fig. 3-1
Rise time Typ. 50ms At 48V, 5A constant current load, 0mF load capacitance,
see Fig. 3-2
Typ. 150ms At 48V, 5A constant current load, 5mF load capacitance,
see Fig. 3-2
Turn-on overshoot Max. 500mV See Fig. 3-2
Input capacitance Typ. 1 650μF Installed inside the device, external capacitors on the
input are allowed without any limitations.
External input protection See recommendations in chapter 2.
Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions
Turn-on
17.5Vdc
V
IN
P
OUT
Shut-down
32.4Vdc
15.5Vdc
18.0Vdc
Rated input range
35.0Vdc
Start-up
delay
Rise
Time
Overshoot
- 5%
Output
Voltage
Input
Voltage
Fig. 3-3 Input current vs. output load
6A
1
23
4
0
2
4
6
8A
5
Output Current
I
n
p
u
t:
4
8
V
d
c
Input Current, typ.
I
n
p
u
t
:
3
6
Vd
c
July 2018 / Rev. 0.1 DS-CD10.482-EN All values are typical figures specified at 48Vdc input voltage 48V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/27