Datasheet
CD10.482
CD-Series
DC/DC Converter 48V/48V, 5A, 240W
PRELIMINARY
22.7. USE IN A TIGHTLY SEALED ENCLOSURE
When the device is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher than
outside. In such situations, the inside temperature defines the ambient temperature for the device.
In the following test setup, the device is placed in the middle of the enclosure; no other heat producing items are
inside the enclosure. The load is placed outside the enclosure.
The temperature sensor inside the enclosure is placed in the middle of the right side of the device with a distance of
1cm.
The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure.
Case A Case B
Enclosure size 110x180x165mm
Rittal Typ IP66 Box
PK 9516 100,
plastic
110x180x165mm
Rittal Typ IP66 Box
PK 9516 100,
plastic
Input voltage 48Vdc 48Vdc
Load
48V, 4A; (=80%) 48V, 5A; (=100%)
Temperature inside the box 43.5°C 48.1°C
Temperature outside the box 26.2°C 26.6°C
Temperature rise 17.3K 21.5K
July 2018 / Rev. 0.1 DS-CD10.482-EN All values are typical figures specified at 48Vdc input voltage 48V, 5A output load,
25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany