Datasheet
CD10.241
CD-Series
DC/DC Converter 24V/24V, 10A, 240W
5. OUTPUT
Output voltage nom. 24V
Adjustment range min. 24-28V *)
max. 30V at clockwise end position of potentiometer
Factory setting 24.1V ±0.2%, at full load, cold unit
Line regulation max. 25mV Input voltage variations between 18 to 35Vdc
Load regulation max. 100mV static value, 0A Æ 10A
Ripple and noise voltage max. 50mVpp 20Hz to 20MHz, 50Ohm
Output capacitance typ. 4 500μF
Output current nom. 12A at 24V, ambient < +45°C, see Fig. 5-1
nom. 10A at 24V, ambient < +60°C, see Fig. 5-1
nom. 7.5A at 24V, ambient at +70°C, see Fig. 5-1
nom. 10.3A at 28V, ambient < +45°C, see Fig. 5-1
nom. 8.6A at 28V, ambient < +60°C, see Fig. 5-1
nom. 6.5A at 28V, ambient at +70°C, see Fig. 5-1
Output power nom. 288W for ambient temperatures < +45°C
nom. 240W for ambient temperatures < +60°C
nom. 180W at +70°C ambient temperature
Short-circuit current min. 13A continuous current, short circuit impedance 100mOhm
max. 15A continuous current, short circuit impedance 100mOhm
*) extended guaranteed adjustment range from 23V to 28V.
Fig. 5-1 Output voltage vs. output current at
24Vdc input voltage, typ.
Fig. 5-2 Current limitation vs. input voltage,
(23V constant voltage load), typ.
Output Voltage
0
048
4
8
12
28V
16
20
24
16
A
62 10 12 14
Adjustment
Range
Output Current
Output Current
21 27
14A
13.0
13.5
36Vdc302418
10.0
10.5
11.0
11.5
12.5
12.0
33
Input Voltage
Apr. 2018 / Rev. 1.2 DS-CD10.241-EN All parameters are typical values at 24V, 10A, 24Vdc input voltage, 25°C ambient and
after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/25