Specifications

Speed control
Continuous shutter
By applying a negative going TTL pulse to pin #8 TRIG
input, the TMC-7 can operate with continuous shutter
speed change. The input pulse must move within a field
timing and the shutter speed is between the pulse edge
and SG1, SG2. In order to activate this function, D0, D1,
D2 must all be low (GND). Unless the TRIG pulse is
applied, CCD charges are kept discharging and when
the pulse is input, the discharge stops and integration
starts up to the transfer gate timing (SG1, SG2).
SECTION 5: RGB OPERATION (Option)
5.1 CCA-7 RGB “BREAKOUT” MODULE
CCA-7 is a compact device designed to accept cam-
era outputs via the 12P-02MF (2 - meter) cable from
the camera, and then output the signals (R, G, B,
Sync, and Video) via standard BNC connectors. It also
accepts 12V DC input via a terminal for power.
Note: RGB option is only available when TMC-7 is
modified for use with CCA-7. Contact PULNiX for
further assistance.
SECTION 6: IMAGER COLOR FILTERS
6.1 DIAGRAM OF COMPLEMENTARY STRIPE
FILTER
6.2 SPECTRAL RESPONSE WITH COMPLE-
MENTARY MOSAIC FILTER
D0
123456
7
0
H
D1
D2
H
H
H
HH
HHH
H
H
H
LLLL
L
L
L
L
L
LL
L
Shutter
speed
Integ-
ration
1/60 1/125 1/250 1/500 1/1000 1/2000 1/4000 1/10000
2FLD 4FLD 6FLD 8FLD 10FLD 12FLD 14FLD 16FLD
(option)
CCA-7
R G B Sync Video
GND +12V
To Camera
(Connect 12P-02MF here)
CY
G
YE
MG
HORIZONTAL SHIFT REGISTER
V SHIFT REGISTER
OUTPUT
COMPLEMENTARY MOSAIC FILTER
CY
CY
G
G
G
YE
YE
MG
MG
MG
CY
G
CY
CY
G
G
G
CY
G
CY
CY
G
G
G
YE
MG
YE
YE
MG
MG
MG
YE
MG
YE
YE
MG
MG
MG
Relative Response
400 500 600 700
Wavelength (nm)
.0
.1
.2
.3
.4
.5
.6
.7
.8
.9
1.0
Cy G
Ye
Mg
9