Page 29
TM/RM/TMC/RMC-4200GE Software
GigE Series Camera Serial Commands
TABLE 5. Command Responses
Command Parameter End Cmd Ack. Response Description
Miscellaneous
:DUL= X <cr> :o<cr> Single Tap/Dual Tap Selection (X = 0 Dual Tap,
X = 1 Single Tap)
:DDP= X <cr> :o<cr> Set Output Data Depth (X = 0 8-bit, X = 1 10-bit,
X = 2 12-bit)
:CCS= X <cr> :o<cr> Select Camera Control signals (X = 0 CL Conn,
X = 1 Hirose Conn)
:TAH= X <cr> :o<cr> External Trigger Polarity (X = 1 Active High,
X = 0 Active Low)
:TPTN X <cr> :o<cr> Enable/Disable Test Pattern
(X = 1 Enable, X = 0 Disable)
:CAM? <cr> :o[model]<cr> Inquire Camera Model
:VER? <cr> :o[version]<cr> Inquire MPU firmware version
:SGE= X <cr> :o<cr> Set Digital Output Interface
(X = 0 CameraLink, X = 1 GigE)
Note: If a command is not accepted for any reason, the camera returns a “nack” response. “:e” <cr> *Not available yet.
Command Parameter End of Cmd Description
Byte 1, 2 Master Gain Master Gain (H'0000 - H'0FFF: -3dB - +12dB)
Byte 3, 4 R Channel Fine Gain R Channel Fine Gain (H'0000 - H'0FFF)
Byte 5, 6 Master Offset Master Offset (H'0000 - H'0FFF)
Byte 7, 8 R Channel Fine Offset R Channel Fine Offset (H'0000 - H'0FFF)
Byte 9 Function Flag 0
Bit 0 Scan Area 0
0000=2048x2048 0001=2048x1000
0010=2048x500 0011=2048x250
Bit 1 Scan Area 1
0100=2x2 binning of 2048x2048
1111=User Programmable Scan Area
Bit 2 Scan Area 2 1000=RPDZ x4 1001=RPDZ x2
Bit 3 Scan Area 3 1000=RPDZ x1.3 1001=RPDZ x1
Bit 4 Rsvd
Bit 5 Rsvd
Bit 6
Pixel Output Order
0
00=<---<--- 01<=<------>
Bit 7
Pixel Output Order
1
10=<<------
Byte 10 Function Flag 1
Bit 0 Shutter 0
Continuous Mode: 0000 - 1001=Continuous preset
shutter 0 - 9
Bit 1 Shutter 1 Trigger Mode:
Bit 2 Shutter 2
0000=Async no shutter 0001 - 1000=Async preset
shutters 1-8
Bit 3 Shutter 3
1001=PWC 1010=PIV Fixed Exposure
1011=PIV PWC