System information

OMI 2.3.1 Release Notes
OMI 2.3.1 Release Notes 53
Images Black on MVS-8100 for Genlocked Sony
XC-75/XC-75CE
Images acquired using a single genlocked XC-75 or XC-75CE camera for triggered
strobed acquisitions are black for approximately 1 out of 200 acquires on the MVS-8100.
Strobe Does Not Fire on First Acquisition
The very first time you acquire a strobed image on an MVS-8100 or MVS-8110, the
strobe does not fire. Perform a dummy acquisition at the start of your application to work
around this problem.
Leftmost Pixels Dark When Using XC-75CE Under
Certain Conditions
If you are using a Sony XC-75 CE camera with an MVS-8110 or MVS-8120 with CVM1 or
CVM6 and the camera format "Sony XC-75CE 380x287 IntDrv (rapid-reset,
shutter-sw-SDONPISHA) CCF", all of the pixels in the leftmost column will be black and
all of the pixels of the next column will be grey.
Pulnix TM-6CN Requires Genlock Enabled on
MVS-8100M and MVS-8100C
If you are using and 8100M or 8100C with the "Pulnix TM-6CN 760x574" video format,
you must enable genlock. You can do this in the Advanced tab of the Image object
dialog box or with the Image objects SetGenlockState() function.
OcvFont Object
ShowExtractArea() Only Works If Dialog Box Is
Open
The OcvFont objects ShowExtractArea() function only works when the OcvFont
objects dialog box is open. If the dialog box is not open, the function has no effect.