System information
OMI 2.3.1 Release Notes
OMI 2.3.1 Release Notes 17
Note CVC-1000 cameras must be connected in camera port order. See
CVC-1000 Usage Notes in the MVS-8110 Hardware Manual for
information on connecting CVC-1000 cameras.
CVM6 Supported Cameras
CVM6 has two independent acquisition channels for digital cameras and one
independent acquisition channel for an analog camera. The cameras that MVS-8110
frame grabbers support on CVM6 are shown in Table 7.
Camera
A /
D
EIA /
CCIR Type
Cognex Camera
Cable Part Number
Hitachi KP-F100 D RS-422 Digital, rapid reset 300-0214 plus
300-0266. Also
requires power
supply equivalent to
Hitachi 45752C1
Sony XC-75 A EIA
RS-170
Interlaced, full,
single-field or
half-resolution
300-0181
Sony XC-75CE A CCIR Interlaced, full,
single-field or
half-resolution
300-0181
Sony XC-55 A EIA
RS-170
Rapid reset, progressive
scan, full resolution; must
be used in E-DONPISHA
II mode (set via switches)
300-0231
Sony XC-55 BB A EIA 300-0136
Sony XC-ST50 A EIA
RS-170
With switches in
free-running mode; full or
half resolution
300-0181
Sony XC-ST50CE A CCIR With switches in
free-running mode; full or
half resolution
300-0181
Table 7. CVM6 supported cameras and cables