Hardware manual

MVS-8100L Hardware Description 2
34 Cognex MVS-8100L Hardware Manual
Schematics for I/O Circuits
This section shows schematic circuit diagrams for the I/O circuits used in the
MVS-8100L.
Trigger Input
Trigger input is used to initiate the acquisition of an image from the currently selected
camera port. A pair of connections (TRIG+ and TRIG–) provide an optically isolated
trigger input. To activate the interrupt, between 4 and 13 volts must be applied to the
terminals. The trigger’s polarity state is programmable via software. The schematic of
the external trigger input circuit is shown in Figure 20.
Figure 20. Trigger input schematic
Status Output
Status output is available for use by your application, as a software controllable parallel
output line. The signal connections are optically isolated. You can use the status output
in one of two ways:
Attach the STSOP and STSOR pins to an optically isolated device.
Attach STSOP to PWR and STSOR to GND, and use STSO as a TTL output (the
current-limiting resistors on PWR and GND protect the MVS-8100L and the host
computer).
TRIG+
VCC
470
1N4148
330
½ W
TRIG–
ILD223