Technical data

-
16
3. Setup of the Baud Rate of Communication. As shown in Figure
2,3 SW2 is used to set the protocol of communication and the baud
rate used by the dome camera. DIP-6 and DIP-5 of SW2 are used to
select the baud rate of communication and 4 different baud rates can
be selected in maximum. If the controller adopts non-standard baud
rate, you can adjust it to be identical with that of the main machine as
per the following table.
Setup of Baud Rate
Baud Rate of
Communication
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
2400 bps OFF OFF
4800 bps ON OFF
9600 bps OFF ON
19200 bps ON ON
Table 3
4. Selection of the Terminal Resistor of the Dome Camera..As
shown in Figure 2、3, JP1 is the select switch of the 120 Ω terminal
resistor on the bus RS485, on which only one terminal resistor of the
dome camera at the farthest end can be connected, while the terminal
resistors of other devices should be opened.