Phau Ntawv Qhia

14
CAUTION
Always insert the filter securely, clean filter once every
two weeks as required.
CARE AND CLEANING
Front Panel and Case
Turn unit o󰀨 and disconnect power supply. To clean, use
water and a mild detergent. DO NOT use bleach and abra-
sivers. Some commercial cleaners may damage the plastic
parts.
Outdoor Coil
Coil on outdoor side of unit should be checked regularly.
Unit will need to be removed to inspect dirt build-up that will
occur on the inside of the coil. If clogged with dirt and soot,
coil should be professionally cleaned. Clean inside and
outside of outdoor coils regularly.
NOTE: Never use a high-pressure spray on coil.
CAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment dam-
age or improper operation. Airflow restriction may cause
damage to the unit.
Air Filters
IMPORTANT: Turn unit off before cleaning.
CAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment dam-
age or improper operation. Do not operate unit without fil-
ters in place. If a filter becomes torn or damaged, it should
be replaced immediately. Operating without filters in place
or with damaged filter will allow dirt and dust to reach in-
door coil and reduce cooling, heating, airflow and efficiency
of unit. Airflow restriction may cause damage to unit.
The most important thing you can do to maintain unit
e󰀩ciency is to clean the lters once every two weeks as re-
quired. Clogged lters reduce cooling, heating, and airow.
Keeping lters clean will:
Decrease cost of operation.
Save energy.
Prevent clogged indoor coil.
Reduce risk of premature component failure.
To Clean Air Filters:
Vacuum o󰀨 heavy soil.
Run water through lter.
Dry thoroughly before replacing.
Figure 14
Figure 15
Vent Door Filter
IMPORTANT: TURN UNIT OFF BEFORE CLEANING.
If the vent door is open, access requires the removal of
the unit from the wall sleeve. Clean the vent lter twice
a year or as required.
Make sure to remove the shipping screw from the vent
door (See Figure 9).
Rotate the vent control lever to open the vent door
(See Figure 16).
Remove four screws from the vent door lter (See
Figure 16).
First pull out the vent door steel wire from the hole of
the vent door, then take o󰀨 the vent door and lter (See
Figure 16).
Clean the lter. Dry thoroughly before replacing.
Replace the vent door and lter,reinstall the four
screws.
Reinsert the vent door steel wire into the hole of the
vent door.