166
5.14 CONFIGURATION COPYING COMMANDS
5.14.1 Copy PowerScan D8330 Series
Procedure:
Connect the master (correctly configured reader) and the slave (reader to be
configured) together through two RS-232 serial interface cables and external
power supply. Accessory cables and power supply are available from your Psion
distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5
Using the slave reader, read the Restore Default barcode and then the RS-232
interface barcode from chapter 4 of this manual or from the Quick Reference
Guide.
With the master reader, read the Configuration Copy barcode below.
Copy Configuration
Ì$+ZZ0$-*Î
The configuration will be copied from the master to the slave reader. The slave
reader signals the end of the procedure with a series of beeps.
NOTE: The master reader can be configured for any interface.