To safely wire power to the 8580/8590, review these guidelines and follow the instructions
that apply to your needs:
• When connecting the cable (PN 13985-301) to the screen blanking cable (PN 1616303-
001), the wire pair on the 13985-301 labelled “screen blanking” connect to the screen
blanking control device, which must provide an isolated relay closure across the pair.
• When connecting the cable (PN 13985-301) to the ignition cable (PN 1616302-001), the
wire pair labelled “screen blanking” on the 13985-301 has a different function; the red
wire must connect to a DC+ voltage source switched on by the ignition, while the black
wire may connect to DC- or be taped off.
• Note that only the ignition function is supported by the UPS (PN PS1110/PS1120), not
screen blanking. If both screen blanking and ignition are to be used on the same
8580/8590, a separate cable must be provided to connect the screen blanking relay
closure to COM2.
Contact Psion for details about the Pre-regulator, model number PS1320 and the Interrupted
Power Supply (UPS), model number PS1110 and PS1120 (freezer unit).
4.5 Cable Cover (Splash Guard)
4.5.1 Protection Class IP65
After finishing the mounting process, the cables must be affixed using the strain relief rail
supplied with your unit.
Warning: For safety reasons, the cable cover supplied for the external ports must be
installed prior to using the 8580/8590. Refer to “Cable Cover, Grounding
Bar & Cables – Assembling” on page 40 for details about installing the
cable cover.
Warning: In order to comply with protection class IP65, please use the optionally
available IP65 assembly kit from Psion. Carefully follow the installation
instructions under the heading “Cable Cover, Grounding Bar & Cables –
Assembling” on page 40.