Fill Chr
This parameter specifies the character that identifies empty entry fields. Enter
the ASCII decimal equivalent of this character. The most commonly used
characters are:
_ (underline) Enter 95
. (period) Enter 46
Note: 8525/8530s in some systems may use the “space” character with the host
using reverse video attributes to mark entry fields.
Upper Case
When this parameter is enabled (set to “Y”), lowercase input is converted
to uppercase.
6.20.2.4 Tests
AutoRep Fn
This parameter determines which function key is sent to the host in auto reply mode.
The value represents the number of the function key – not the ASCII decimal
equivalent. After sending this key, the unit locks and waits for the host to unlock the
8525/8530. To disable “AutoRep Fn”, set the “AutoRep T/O” parameter to zero.
AutoRep T/O
This parameter determines the time (in seconds) between the 8525/8530 unlocking
and the next transmission of the function key specified by the above parameter.
A value of zero disables auto reply mode.
AutoRep Fn 7 0..63
AutoRep T/O 5 0..255