User manual

Chapter 5: Configuration
Protocol Tab
104
Psion Teklogix 8525/8530 Vehicle-Mount Computer User Manual
Poll Timeout
This parameter (in units of 16.6 ms) sets the time-out value used for automatic
channel switching. “Poll Timeout” is the time during which the 8525/8530 should
detect at least one poll from a base station. As each “Poll Timeout” passes without a
successful poll from the base station, the 8525/8530 channel quality decreases. If the
channel quality falls to below 46%, the terminal begins searching for a new channel.
A value from 1 to 200 can be assigned to this parameter.
Late TX Limit
The value entered for this parameter (measured in milliseconds) sets the maximum
allowable deviation time from the start of a response window during which an
8525/8530 can make a transmission. After this threshold, the transmission will not
be attempted and the 8525/8530 will try again at the next opportunity. For example,
suppose this parameter is set to 5. From the beginning of the response window, the
8525/8530 can be up to 5 milliseconds late sending a transmission. Beyond this
threshold, the transmission is not attempted. The vehicle-mount waits for the next
opportunity.
The allowable range for this parameter is from 1 and 10 – the default value is 2.
Test Polling Values
Tap on the Test Polling Values button to test the polling values indicated in
this dialog box without committing them to memory.
To commit the new polling values to memory:
Tap on the OK button – the dialog box is closed and the new values
are saved.
To discard the new values, and retain the existing values:
Tap on the X button at the top of the dialog box.